TI RM48Lx
The TI RM48Lx are high-performance, safety-critical Cortex-R4F based microcontrollers, designed for real-time automotive and industrial applications with built-in functional safety features.
Flash Banks
RM48L5x, RM48L7x
| Flash bank | Base address | J-Link support | Flasher support | Loader | |
|---|---|---|---|---|---|
| Name | Bank size | ||||
| Internal flash | 0x00000000 | Default | 2048 KB | ||
| No_auto_ECC | 2048 KB | ||||
| EEP flash | 0xF0200000 | Default | 64 KB | ||
| No_auto_ECC | 64 KB | ||||
| OTP flash | 0xF0000000 | Default | 4 KB | ||
RM48L9x
| Flash bank | Base address | J-Link support | Flasher support | Loader | |
|---|---|---|---|---|---|
| Name | Bank size | ||||
| Internal flash | 0x00000000 | Default | 3072 KB | ||
| No_auto_ECC | 3072 KB | ||||
| EEP flash | 0xF0200000 | Default | 64 KB | ||
| No_auto_ECC | 64 KB | ||||
| OTP flash | 0xF0000000 | Default | 4 KB | ||
ECC flash automatic generation
- When programming internal Flash or EEPROM banks, ECC is generated automatically when using the “Default” loader and is not generated when using the “No_auto_ECC” loader.
ECC RAM
- RAM is initialized during target setup phase.
Watchdog Handling
- The device has two watchdogs DWD and DWWD.
- The watchdog are fed during flash programming.
Device Specific Handling
Reset
- The device uses custom reset: Reset is performed using reset vector catch feature and ICEPick interface trigger.
Limitations
Dual Core Support
- Although the RM48Lx series is a dual Cortex-R4F MPU, the cores always operate in lock-step mode (synchronous operation for redundancy and safety).
Attach
- Attach is not supported by default because the J-Link initializes RAM for correct ECC operation by default.
Security
RM4x devices can be protected against unauthorized access to device memory and the ARM debug interface.
Lock procedure
To enable protection, a 128-bit key must be programmed into OTP memory at address 0xF00000000. The key can be programmed multiple times, subject to the following restriction: OTP memory only supports bit transitions from 1 to 0. Since this memory is protected by ECC, the same restriction applies to the corresponding ECC bits. Therefore, neither the new unlock key value nor its ECC code may contain any bit transitions from 0 to 1. TI provides the HAL Code Generator tool to generate a new key based on the currently programmed key. The default TI Visible Unlock Key is stored at address 0xF00000000 and consists of the following 32-bit words:
| Byte offset | Value |
|---|---|
| 0x00 | 0xEFFDFFFF |
| 0x04 | 0xFFFFFFFF |
| 0x08 | 0xFFFDFFFE |
| 0x0C | 0xFFEFFFFF |
Unlock procedure
A protected device can be unlocked using J-Link Commander or J-Flash. When J-Link detects a locked device, it prompts the user to enter the 128-bit unlock key. Alternatively, the key can be specified using the SetCPUConnectIDCODE J-Link command string. Both the J-Link command string and the unlock dialog expect the key as a raw byte stream in memory order, with the least significant byte of each 32-bit word first.
For example, key generated by HAL Code Generator:
Offset 0x00: 0xC7E58FCE Offset 0x04: 0xF573EAE6 Offset 0x08: 0xF5CDEB9E Offset 0x0C: 0x30026024 J-Link key input: CE8FE5C7E6EA73F59EEBCDF524600230